America UL CSA PVC Power Cable

PVC Flexible Cable products with UL cUL certifications for North America as Unite states and Canada.100% of us are high quality molded power cords and RoHS compliant. 
America UL CSA PVC power cable SPT
UL Style & Conductor NO. Insulation Overall Standard Length CSA Type of Thickness Diameter Core mm mm AWG NO./mm Ft/coil M/coil SPT-1 18 41/0.160 2 0.76 2.70×5.40 1000 305 3 2.70×8.00 SPT-2 18 41/0.160 2 1.14 3.50×6.90 1000 305 16 65/0.160 3.70×7.20 18 41/0.160 3 3.50×8.60 16 65/0.160 3.80×9.60 SPT-3 18 41/0.160 2 1.52 4.40×8.70 1000 305 16 65/0.160 4.60×9.10 14 41/0.254 2.03 6.00×10.80 500 152 12 65/0.254 2.41 7.40×14.00 10 104/0.254 2.79 9.10×18.20 18 41/0.160 3 1.52 4.40×10.70 1000 305 16 65/0.160 4.70×11.60 500 152 14 41/0.254 2.03 6.00×14.50 12 65/0.254 2.41 7.30×16.50 10 104/0.254 2.79 9.10×18.80 UL20288 18 41/0.160 2 1.02 3.25×5.80 1000 305 Other Termination Options: Click Here
Viewdetail
America UL CSA PVC power cable NISPT
Type Conductor Insulation Thickness Jacket Thickness Overall Diameter Min.Cross-sectional area of Conductor Size规格 No/mm [mm] [mm] [mm] [mm2] S 18AWG/2C 41/0.160 0.76 1.52 8.60±0.15 0.798 SO 16AWG/2C 65/0.160 0.76 1.52 9.20±0.15 1.27 SOO 14AWG/2C 41/0.254 1.14 2.03 12.5±0.20 2.02 SOW 18AWG/3C 41/0.160 0.76 1.52 9.00±0.15 0.798 SOOW 16AWG/3C 65/0.160 0.76 1.52 9.70±0.15 1.27 14AWG/3C 41/0.254 1.14 2.03 13.2±0.20 2.02 18AWG/4C 41/0.160 0.76 1.52 9.70±0.15 0.798 16AWG/4C 65/0.160 0.76 1.52 10.5±0.20 1.27 14AWG/4C 41/0.254 1.14 2.03 14.2±0.20 2.02 18AWG/5C 41/0.160 0.76 2.03 11.5±0.20 0.798 16AWG/5C 65/0.160 0.76 2.03 12.4±0.20 1.27 14AWG/5C 41/0.254 1.14 2.41 16.2±0.20 2.02 Other Termination Options: Click Here
Viewdetail
America UL CSA PVC power cable SJT SJTW SJTOW
Type Conductor Insulation Braid Jacket Overall Standard Length Thickness Shield Thickness Diameter mm mm mm mm AWG No./mm Ft/coil M/coil SJT.SJTO 18×2c 41/0.160 0.76 - 0.76 7.30±0.15 1000 305 SJTW.SJTOW [unshielded] 16×2c 26/0.254 - 8.00±0.15 14×2c 41/0.254 - 8.70±0.15 .SJTOOW 12×2c 65/0.254 - 1.14 9.90±0.15 10×2c 65/0.320 1.14 - 1.52 13.70±0.20 18×3c 41/0.160 0.76 - 0.76 7.80±0.15 16×3c 26/0.254 - 8.50±0.15 [unshielded] 14×3c 41/0.254 - 9.30±0.15 12×3c 65/0.254 - 1.14 10.80±0.15 10×3c 105/0.254 1.14 - 1.52 14.4±0.20 Other Termination Options: Click Here
Viewdetail
America UL CSA PVC power cable SVT
UL Style Conductor Insulation Braid Jacket Overall Standard Length & Thickness Shield Thickness Diameter CSA Type AWG No./mm mm mm mm mm Ft/coil M/coil SVT[unshielded] 18×2c 41/0.160 0.38 - 0.76 5.90±0.10 1000 305 18×3c 41/0.160 - 6.30±0.10 SVT[shielded] 18×2c 41/0.160 0.38 - 0.76 5.90±0.10 1000 305 18×3c 41/0.160 - 6.30±0.10 SVT[shielded] 18×3c 41/0.160 0.38 16/8/0.12 0.76 7.20±0.15 1000 305 Other Termination Options: Click Here
Viewdetail
  • Copyright©1997-2016 Ningbo Yunhuan Group Strong Power Electronics Corp